| 1) Physical Specications |
| |
Height: 3U (132.5mm) |
| |
Width: 429mm across Chassis (not including Chassis mounting
brackets) 482.6mm across Chassis mounting brackets |
| |
Length: 520mm Chassis (including Chassis mounting bracket
cover plastics) 502mm Chassis mounting bracket face to end of
Chassis 550mm Overall (Chassis mounting bracket plastics – PSU
Flap Wire Guard) |
| |
Weight: 38Kg with 250GB Drives (Rack Slides NOT included) |
| |
Power: 2 x 400W load sharing PSUs (12V / 5.1V / 3.3V / 1.8V) |
| |
Cooling: 2 x Radial Blowers per PSU – 4 total (4,200 / 4,500 rpm
Max) software speed controlled |
| 2) Communication |
| |
10/100/1000 Base-T Ethernet RJ45 (two per controller, one for
future use) |
| |
Supports TCP/IP, HTTP, SMTP, SNMP traps, Daytime and FTP |
| |
GUI HTML supported by most Internet browsers |
| |
Email sent via SMTP in event of failure or warning event |
| |
Trap sent via SNMP in event of failure or warning event |
| |
RS232 Serial Interface DB9 (one per controller) |
| |
Supports VT100 |
| |
Compatible with terminal emulation software such as Hyper
Terminal and Kermit |
| 3) External Data Interface |
|
| |
Dual port, 2Gb Fibre Channel (2 host ports per controller)
Single iSCSI controller port per controller |
| 3)Technical Specications |
| Hard disk interface |
SATA (14 channels) |
| Host Channel interface |
Dual 2Gb Fibre ports, Single iSCSI controller port per controller |
| Controller |
Single or dual controller, Active-Active failover, cache corehency |
| Cache |
512MB per controller (expandable to 2GB) |
| Drive bay size |
14 bays / 3U |
| Battery backup |
Yes |
| Raid level |
0,1,1+0,4,5 and 6 |
| Sustained data rates |
Up to 370MB/sec per controller |
| LUN supported |
32 |